MHS-5200-06M
The instrument Introduction
MHS-5200A series instruments using large scale integrated circuits and high-speedFPGA MCU microprocessor,
the internal circuit to take surface mount technologyhas greatly enhanced the instrument\'s noise immunity and service life.
Displayinterface using LC1602 LCD display is divided into two lines, the top line showsthe current frequency,
the following line displays additional parameters or functionvariable and flexible use of flip key setting, greatly enhances the operability.
This instrument signal generation, waveform scanning, as well as the useof parameter measurement has great advantages,
is an electronic engineer,electronic laboratories, production lines and teaching, research and the idealtest, measurement equipment.
Model Description
This series of instruments in four models, the main difference is themaximum frequency sine wave, as follows:
MHS-5200-06M sinusoidal signals at frequencies up to 6MHz
MHS-5200-12M sinusoidal signals at frequencies up to 12MHz
MHS-5200-20M sinusoidal signals at frequencies up to 20MHz
MHS-5200-25M sinusoidal signals atfrequencies up to 25MHz
The instrument characteristics:
1.Direct digitalsynthesis (DDS) technology, FPGA design, low power consumption;
2.Dual output, canwork in sync phase adjustable;
3.It has up to 500seconds of linear and logarithmic sweep function Sweep;
4 .With a sine wave,triangle wave, square wave, sawtooth rise, falling sawtooth waveform basicfunction and variable duty cycle pulse wave, but also has 16 sets of arbitrarywaveform customized by the user;
5.A total of 10 setsof parameters stored bits have M0 - M9, M0 boot automatically transferred outof data;
6.At 12MHz or less,the sharpest of up to 15Vp-p, more than 12MHz, the biggest reach 8Vp-p;
7.Built precision-20dB attenuator reach the minimum amplitude resolution 1mV;
8.With a 120% - + 120%DC bias function;
9.Pulse Duty preciseadjustment to 0.1%;
10.Having fourvariable phase difference of TTL output;
11.Having a frequencymeasurement, period measurement, positive and negative pulse width measurement,duty cycle measurements and counting function;
12.Four optional gatefrequency measurement time, which strike a balance between speed and accuracy;
13.All parametricequalizer can be done by an internal calibration procedure;
14.Powerfulcommunications features, completely open communication protocol that allows thesecondary development of very simple;
15.After connectingwith the PC, the PC can be used to control the instrument, and can be edited onthe PC arbitrary waveform output waveform is downloaded to the instrument.
16.This type machinecan be equipped with an increase in power module, the signal output amplitudereaches 30Vpp, the maximum output current reaches 1A;
Specifications:
Key Features Frequency
Range Sine wave Normal mode:
MHS-5200-06M:0Hz-6MHz;
MHS-5200-12M:0Hz-12MHz;
MHS-5200-20M:0Hz-20MHz;
MHS-5200-25M:0Hz-25MHz。 Square wave 0Hz-6MHz Triangle wave 0Hz-6MHz Sawtooth 0Hz-6MHz Arbitrary Waveform 0Hz-6MHz TTL Digital signal wave 0Hz-6MHz Output modulation Frequency sweep Waveform types Sine, square, triangle, sawtooth lift, TTL digital signal wave, Arb Waveform Length 1024 Point Sampling rate 200MSa/s Waveform amplitude
resolution 8bits The minimum frequency
resolution 10mHz Frequency error ±5x10-6 Frequency stability ±1x10-6 Amplitude range
(peak to peak) 15mVp-p~15Vp-p(12MHz or less)
15mVp-p~8Vp-p(12MHz above Output Impedance 50Ω±10% Amplitude resolution 1mVp-p(-20dBAttenuation)
10mVp-p(Does not decay) Amplitude stability ±0.5%(Every five hours) Amplitude error ± 1%+10mV(Frequency1KHz,15 Vp-p) Offset Range -120% to +120%(The ratio of the bias voltage and signal amplitude) Bias Resolution 1% Phase range 0-359° Phase resolution 1° Sine wave Harmonic arrived
System 40dBc(<1MHz) ,35dBc(1MHz~20MHz) Distortion <0.8%(20Hz~20KHz) Square wave Lifting along time ≤20ns Overshoot ≤10% Duty cycle
adjustment range 0%-99.9% TTL Lifting along time ≤20ns LOW <0.3V High 1V-7.5V Arbitrary Waveform Quantity 16 groups Memory depth /
group 1KB / 16 group Scan Scan Mode Linear sweep, log sweep Scan time 1S-500S Scan range It is determined by the sweep parameter settings External
measurements Frequency range GATE-TIME=10S 0.1HZ - 60MHZ
GATE-TIME=1S 1HZ - 60MHZ
GATE-TIME=0.1S 10HZ - 60MHZ
GATE-TIME=0.01S 100HZ -60MHZ Input voltage range 0.5Vp-p~20Vp-p Counting range 0~4294967295 Counting Manually Positive and negative pulse width measurement 10ns resolution, the maximum measurable 10s Periodic measurements 20ns resolution, the maximum measurable 20s Duty Cycle
Measurement 0.1% resolution, measuring range from 0.1% to 99.9% Source Selection 1.Ext.IN input (AC signal),
2.TTL_IN input (digital signal) Memory Memory 10 Location M0-M9 Interface Interface Using USB to serial interfaces Communication
rate 57600bps Protocol Using the command line, the agreement public Power supply DC DC 5V Size Length x width x
height 180x190x71mm Weight Single 546g
Accessory:
Power Adapter (US, UK,Euro or AU plug) x1;
USB cable x1;
Signal connectioncable x2;
User Manual (pdfversion) x1.
Note: we\'ll ship this item viaexpress mail serviceto USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia, Philippine, Singapore.
Clients from other countries pls contact with us in advance to confirm the different shipping charges before you order.