S&A CW-5000DH Water Chiller for 5KW Spindle /Welding Cooling 110V, 60Hz For Sale


S&A CW-5000DH Water Chiller for 5KW Spindle /Welding Cooling 110V, 60Hz
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.



Buy Now

S&A CW-5000DH Water Chiller for 5KW Spindle /Welding Cooling 110V, 60Hz:
$581.03

Note: The Water Chiller is ordering production, need 3 to 5 days of stock up time.Comprehensive guarantee for 2 years except the wearing parts.

It is designed for cooling a single 5KW spindle of the cnc engraving machine.
Cooling capacity is 800W.
Have design patent Certificate, CE and RoHS Certificate.
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movableFeatures
• It is designed for cooling a single 5KW spindle of thecnc engraving machine.•You can choose different model according to local voltage and frequency.•Small thermolysis water cooler, energy saving, long working life and simple operation•With completed water flow and over high temperature alarm functions•It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices.•This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement.• Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;•Specific disconnection alarm securing protection.•Enclosed water tanks, water used for a long time.•Equipped with alarm output port, can quickly protect sensitive components.•High cost performance, low failure rate.
• Multiple power specifications; CE approval; RoHS approval.ModelCW-5000DHPower SupplyAC 1P 110V,60HzCurrent3.5 – 5.6ACompressor Power0.305KW0.41HPRefrigerating Capacity2866Btu / h0.84KW722Kcal / hRefrigerantR – 134aRefrigerant Charge280gPrecision±0.3℃Tank current protection for compressor, flow alarm, over temperature alarmPump Power0.03KWMaximum Flow10L / minMaximum Pumping Lift10MInlet and OutletExternal Dia.: 10mm brass connector


Alarm function

E1E2E3E4E5Over high room temperatureOver high water temperatureOver low water temperatureRoom temperature sensor failureWater temperature sensor failure
Remark:When alarm occurs, the error code and the temperature will be alternately displayed.In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display
remains until the alarm condition is eliminated.
Thermostat parameters list:OrderCodeProject settingF9 – F825Constant temperature control effecting2F1Temperature difference values-15 - +5-2Intelligent control effecting3F2Cooling hysteresis0.1 – 3.00.84F3Way of control0 - 111: intelligent0: constant temperature5F4Alarm for over high water temperature1 - 20106F5Alarm for over low water temperature1 - 20157F6Alarm for over high room temperature40 - 50458F7Password00 - 9989F8The allowed highest water temperatureF0 - 403010F9The allowed lowest water temperature1 – F020P.S.: cooling water additive is forofferden by express company, so we could not put it into the package. You can buy it from local.

Temperature controller panel:Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling
parameters. It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines.Alarm Function’s Description:
Flow alarm and output ports
In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.The cooling water circulation loop alarm causes and the work of the state table

Normal FlowIndicatorFlow AlarmIndicatorBuzzerOutput PortsHi, H2Output PortsH1, H3Circulating pump works properlyONOFFNOT RINGDISCONNECTIONBREAKOVERBlocked cooling water circulation of water circulating interruption///BREAKOVERDISCONNECTION


Note:The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

Our water cooling machine has S & A logo
on the top of injection port. Fake cooler without the logo.Our water chiller has function of Intelligent temperature controlFake cooler without this function.Our water chiller has S & A trademark in this label.This image is only to show the brand, specific parameters will vary depending on the model,please refer to the specifications table parameters prevail.Fake cooler without this trademark. Our water chiller has S & A logo on the outfall Fake cooler without this logoS & A trademark is printed on our water chiller. Fake cooler without this trademarkIndustrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps.
A.Open the package to check if the machine is intact and all the necessary accessories are completed.
B. Open the injection port to feed cooling water.Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.
C.According to system conditions, please connect the water inlet and outlet pipe well.
D.Plug in power, turn on the power switch. (Do not start up without water in the water tank!)(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.(2) After the first boot, you must immediately check whether the water pipe leaks.(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.
E. Check the water level in the water tank.The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.
F.Adjust parameters of temperature controller.
CW-5000series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.”MaintenanceCooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation. You can use non – corrosive antifreeze if you are in the northern cold regions.
Cautions1. Please ensure that thepower supplyand electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).
2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model
is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
3. To protect the pump, it’s strictly forofferden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!
4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.
5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.
6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.


Quality Report:

Wooden Box:There is total one carton box.Machine Dimension550mm x 280mm x 430mm (21.6\" x 11\" x 17\")Machine Weight57.2ib (26kg)PackageCarton boxPacking Size720mm x 440mm x 620mm (28\" x 17\" x 25\")Gross Weight68.2ib (31kg)

Packing List:

CW5000 water chiller machine1 setPower cable1 pcConnection hose1 pcSealing washer2 pcs250V/2A spare fuse
(Mounted on the power socket
interface within the insurance reserve)1 pcUser manual1 pcAlarm signal output plug1 pc


Caution:The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction, children supervised not to play with the appliance!Package:


On May-26-16 at 02:01:51 PDT, seller added the following information:

On Nov-07-16 at 03:02:12 PST, seller added the following information:


Buy Now


 

Hydroponic Forum Discussions: